Zebra Technologies R110PAX4 Printer Accessories User Manual


 
99
Routine Maintenance
Power Fuse Replacement
6/29/11 110PAX4/R110PAX4 User Guide 57512L-004 Rev. A
Power Fuse Replacement
The print engine uses a metric-style fuse (5 × 20 mm IEC) rated for 5 Amps at 250 Volts that
bears the certification mark of a known international safety organization (see Figure 11
on page 34). The power entry module comes with two approved fuses in the fuse holder: one is
in-circuit, and the other is a spare.
To replace a fuse, complete these steps:
1. Turn Off (O) the print engine and unplug the power cord from the back of the print engine.
2. Using a small-blade screwdriver, remove the fuse holder from the power entry module at
the rear of the print engine.
3. Carefully remove the fuse from the in-circuit location.
4. To remove the spare fuse, gently push the point of a pencil or the end of a paperclip
through one of the two holes in the fuse holder. Repeat through the other hole.
5. Insert the spare fuse in the in-circuit location.
6. Place a new fuse in the spare fuse location.
7. Reinstall the fuse holder into the power entry module at the rear of the print engine.
8. Reconnect the power cord, and then turn On (I) the print engine.
The print engine should be ready for operation and the POWER light should be on. If
power is not restored, an internal component failure may have occurred, and the
print engine may require servicing.
Caution • Turn Off (O) the print engine and disconnect it from the power source before
performing the following maintenance.