Zebra Technologies XiII-Series Printer User Manual


 
Cleaning the Cutter Module
(For printers equipped with the optional cutter.)
The Cutter Module requires periodic cleaning to remove paper dust and
gummed label residue. The procedure should be performed by the operator
as needed to ensure proper cutter action. If labels are not being cut properly,
or if the cutter jams with labels, this is an indication that the cutter probably
needs cleaning. The cleaning frequency depends on your application and
media type.
Clean the stationary cutter blade with cleaning solvent when it becomes
gummed up with label adhesive and/or paper debris. If further cutter clean
-
ing is necessary, or if the cutter performs unsatisfactorily, contact a service
technician.
Lubrication
CAUTION! No lubricating agents of any kind should be used on
this printer! Some commercially available lubricants
will damage the finish and the mechanical parts if
used.
Fuse Replacement
The Zebra XiII printer uses a metric-style fuse (5 X 20 mm IEC) rated at
F5A, 250V. The end caps of the fuse must bear the certification mark of a
known international safety organization (See Figure 20, “International
Safety Organizations,” on page 82). The printer comes with two approved
fuses: one in the circuit and one in the “spare fuse” holder.
1. Turn the printer power off and unplug the power cord from the back of
the printer. See Figure 12.
2. Using a small-blade screwdriver or similar tool, remove the Fuse
Holder from the printer.
54 Zebra XiII-Series User’s Guide
66
H:...Xi2UsersGuideR2.vp
Fri Aug 07 10:36:17 1998
Color profile: Disabled
Composite Default screen