Zebra Technologies ZM600 Printer User Manual


 
Configuration
Standard Control Panel Parameters
90
79695L-003 Z Series
®
/RZ™ Series User Guide 1/11/11
ZPL only Set Control Prefix Character
The printer looks for this two-digit hex character to indicate the start of a
ZPL/ZPL II control instruction.
Note • Do not use the same hex value for the control, format, and
delimiter character. The printer must see different characters to
work properly.
Default Value: 7E ~
Range: 00 to FF
To change the value shown:
1. Press SELECT to select the parameter.
2. Press MINUS (-) to move to the next digit position.
3. Press PLUS (+) to increase the value of the digit.
4. Press SELECT to accept any changes and deselect the parameter.
ZPL only Set Format Prefix Character
The format prefix is a two-digit hex value used as a parameter place marker
in ZPL/ZPL II format instructions. The printer looks for this hex character
to indicate the start of a ZPL/ZPL II format instruction. See the
Programming Guide for ZPL, ZBI, Set-Get-Do, Mirror, and WML for more
information.
Note • Do not use the same hex value for the control, format, and
delimiter character. The printer must see different characters to
work properly.
Default Value: 5E ^
Range: 00 to FF
To change the value shown:
1. Press SELECT to select the parameter.
2. Press MINUS (-) to move to the next digit position.
3. Press PLUS (+) to increase the value of the digit.
4. Press SELECT to accept any changes and deselect the parameter.
Table 11 • Printer Parameters (Page 18 of 25)
Language/Parameter