Znyx Networks bh5700 Switch User Manual


 
M States
M5 Deactivation request (e.g. hot swap ejector opened)
M6 Deactivation granted by ShMC
M7 Unexpected loss of communication between FRU and ShMC
Table C.1.: IPMI M States
Peripheral Management Controller Functional Support
The following IPMI commands are implemented in version 1.00:
PMC Controller Support
Command Code Sensor # Status Notes
GetDevID 0x01 Mandatory
BroadcastGetDeviceID 0x01 Mandatory
ColdReset 0x02 Optional
GetSelfTestResult 0x04 Mandatory
GetSensorReading 0x2D Mandatory
TempSensor 60 Returned in Celsius
A2D_0 41
A2D_1 42
A2D_2 43
A2D_3 Not used
A2D_4 45
A2D_5 Not used
Full 8-bit value (255)
represents 3.3 Volts;
scale returned value
accordingly
SetSlotPower 0x12 Vendor
specific
SetSlotBlueLed 0x13 Vendor
specific
SetSlotReset 0x15 Vendor
specific
Table C.2: PMC Controller Support
Ethernet Switch Blade User's Guide release 3.2.2j page 349