Znyx Networks bh5700 Switch User Manual


 
# Fabric portions of the 7100 switch. The actual coordination
is dependent on the
# setting of the board_synchronization_mode and the
failover_mode. In
# switch failover_mode the number of up links in both switch
planes is
# considered. In vlan and port failover mode they are not. In
all
# failover_modes, if the data plane or fabric plane switch
reboots or
# power cycles, the HA partner will take mastership for all
VLANs in
# both planes. board_synchronization is off by default.
"basic" is the
# only supported mode at this time. The same mode must be set
in both
# the base and fabric switches.
#board_synchronization_mode: basic;
# vrrpd_script: Allows the user to add scripts to be executed
during
# vrrpd state transitions. These scripts are run from the end
of the
# /etc/rcZ.d/surviving_partner/vrrpd.script file. The user
provided
# script must be well behaved. If it crashes, or hangs or
delays it will
# effect the SurvivingPartner performance. The script is not
run in
# backround. If this is needed, have your script background
itself.
#vrrpd_script: /etc/rcZ.d/surviving_partner/my_vrrpd_script;
#vrrpd_script: /etc/rcZ.d/surviving_partner/my_vrrpd_script2;
Ethernet Switch Blade User's Guide release 3.2.2j page 41