Chapter 37 System Information and Diagnosis 383
Figure 228 Menu 24.2.2 System Maintenance: Change Console Port Speed
Once you change the Prestige console port speed, you must also set the speed parameter for
the communication software you are using to connect to the Prestige.
37.4 Log and Trace
There are two logging facilities in the Prestige. The first is the error logs and trace records that
are stored locally. The second is the syslog facility for message logging.
37.4.1 Viewing Error Log
The first place you should look for clues when something goes wrong is the error log. Follow
the procedures to view the local error/trace log:
1 Type 24 in the main menu to display Menu 24 – System Maintenance.
2 From menu 24, type 3 to display Menu 24.3 – System Maintenance – Log and Trace.
Figure 229 Menu 24.3 System Maintenance: Log and Trace
3 Enter 1 from Menu 24.3 — System Maintenance — Log and Trace to display the error
log in the system.
After the Prestige finishes displaying the error log, you will have the option to clear it.
Samples of typical error and information messages are presented in the next figure.
Menu 24.2.2 – System Maintenance – Change Console Port Speed
Console Port Speed: 9600
Press ENTER to Confirm or ESC to Cancel:
Menu 24.3 - System Maintenance - Log and Trace
1. View Error Log
2. UNIX Syslog
Please enter selection