A SERVICE OF

logo

---- ---------------------------------------- -------- ---------- ----------
Redundancy (Switches 8200zl)
Downloading a New Software Version
ProCurve(config)# show version
Management Module 1: Active
Image stamp: /sw/code/build/btm(t2g)
Mar 15 2007 12:28:32
K.12.30
64
Boot Image: Primary
Management Module 2: Standby
Image stamp: /sw/code/build/btm(t2g)
Mismatch exists
Mar 21 2007 14:24:38
K.12.30
789
Boot Image: Secondary
ProCurve(config)# show redundancy
Settings
------- -
Mgmt Redundancy : Enabled
Statistics
--------- -
Failovers : 0
Last Failover :
Slot Module Description Status SW Version Boot Image
1 ProCurve J9092A Management Module 8200zl Active K.12.30 Primary
2 ProCurve J9092A Management Module 8200zl Standby K.12.30 Primary
1 ProCurve J9093A F2 Fabric Module 8200zl Enabled
2 ProCurve J9093A F2 Fabric Module 8200zl Enabled
Warning: Standby module is running a different software version and may be using
a different configuration file. Configuration changes on active management
module may not take effect on a failover.
Figure 15-11. Example of a Software Version Mismatch Between the Active and Standby Modules
15-20