1-12 Intel® Server RAID Controller U3-1 User’s Manual Rev 1.0
Quick Start Instructions
5. It will eventually load a Welcome screen, asking you to verify the startup directory
(C:\NWSERVER). Hit Alt F10 to exit the installation. At the console, type Down.The
installation exits to the boot drive prompt.
6. Insert the SRCU31 NetWare installation diskette created in step 1. into the A: drive. If your
boot drive is C:, then run NWUPDATE.BAT. If your boot drive is other than C:, then create an
NWUPDATE subdirectory and copy all the files from A:\DRIVERS into the NWUPDATE
subdirectory.
7. Remove the diskette from the A: drive and reboot the server. After booting you will be asked
to accept the license agreement. Do so and then select Continue with Existing Partition.You
are now ready to install NetWare 5 on the Intel Integrated RAID volume.
8. Continue with the NetWare installation as normal by following the screen prompts. Select the
Block Storage OSM when prompted.
9. Reboot the server and install Service Pack 4 or higher. Once the server installation is
completed, reboot the server.
10. To install the Intel Integrated RAID software (run the Intel Integrated RAID setup) run
NWCONFIG.
11. Select Product Options,thenInstall product not listed. It will tell you that it is going to scan
the A: drive for installation scripts. Ensure the SRCU31 NetWare Installation diskette is in the
floppy drive, hit Enter to continue.
12. A screen prompt will ask which components (see below) you wish to install. Select the
following components and hit F10 to continue. See Figure 1-5.
BKSTROSM.HAM
HTTP and Winsock Services
RAID Management Agents
Figure 1-5. Component Installation
The appropriate files are copied and the AUTOEXEC.NCF and STARTUP.NCF files are
modified as necessary.
13. After the installation is complete, reboot the server.