258 Supply position must be -300 - 300 dots.
259 Contrast adjustment must be -390 - 156 dots.
260 Print adjustment must be -99 - 99 dots.
261 Margin adjustment must be -99 - 99 dots.
262 Speed adjustment must be 0 (default), 20 (2.0 ips), 30
(3.0 ips), 40 (4.0 ips), or 50 (5.0 ips).
263 Primary monetary symbol is invalid.
264 Secondary symbol selection must be 0 (none) or 1
(print secondary sign).
265 Monetary decimal places must be 0 - 3.
266 Character string length in the control characters packet
must be 5 (MPCL control characters) or 7 (ENQ/IMD
command character)
267 Baud rate selection must be 0 (1200), 1 (2400), 2
(4800), 3 (9600), 4 (19200), or 5 (38400). Resend the
communication settings packet.
268 Word length selection must be 0 (7 bits) or 1 (8 bits).
Resend the communication settings packet.
269 Stop bits selection must be 0 (1 bits), or 1 (2 bits).
Resend the communication settings packet.
270 Parity selection must be 0 (none), 1 (odd), or 2 (even).
Resend the communication settings packet.
271 Flow control selection must be 0 (none), 1 (DTR), 2
(CTS/RTS), or 3 (XON/XOFF). Resend the
communication settings packet.
272 Internal code page selection must be 0 (Internal), 1
(ANSI), 2 (DOS 437), or 3 (DOS 850).