36 APPENDIX A: SAFETY INFORMATION
Important Safety
Information
Installation and removal of the EPS must be carried out by qualified
personnel only.
Always connect the EPS to an earth (ground) connection when you
connect it to an AC outlet (power supply).
To comply with European safety standards, the EPS must always be
connected to an earthed (grounded) outlet.
The power cord set must be approved for the country in which it is
used, as indicated in Table 9.
The appliance coupler (which is the connector to the unit, not to the
wall) must have a configuration for mating with an EN60320/IEC320
appliance inlet.
The socket outlet must be near to the unit and easily accessible. You
can remove power from the unit only by disconnecting the power
cord from the outlet.
This unit operates under SELV (Safety Extra Low Voltage) conditions
according to IEC 950. These conditions are maintained only if the
equipment to which it is connected also operates under SELV
conditions.
Switzerland only:
The supply plug must comply with SEV/ASE 1011.
Table 9 International Safety Information
U.S.A. and
Canada
The cord set must be UL-approved and CSA certified.
The flexible cord must meet these minimum specifications:
No. 18 AWG
Type SV or SJ
3-conductor
The cord set must have a rated current capacity of at least
10A.
The attachment plug must be an earth-grounding type
with a NEMA 5-15P (15A, 125V) or NEMA 6-15P
(15A, 250V) configuration.
Denmark The supply plug must comply with section 107-2-D1,
standard DK2-1a or DK2-5a.
Switzerland The supply plug must comply with SEV/ASE 1011.