Patrol Scrub Enables or disables the hardware patrol
scrub to clean correctable errors.
Enabled
Disabled
Retest all
System
Memory
If enabled, retest all memory in the
system (including disabled DIMMs) and
enables memory which passes the test.
This option will reset to Disabled after
the test is completed.
Disabled
Enabled
Sparing
Threshold
Set the number of correctable errors
that can be logged in a period before
memory sparing occurs. Refer to “To
configure memory sparing” on page
168 for more details.
15
1, 2, 3, 4, 5, 6,
7, 8, 9, 10, 11,
12, 13, 14
RAID Upgrade
Gap
Size of reserved gap on each memory
board for RAID memory capacity
addition.
Disabled
512MB
1024MB
1536MB
2048MB
2560MB
3072MB
3584MB
4096MB
Desired
Memory
Configuration
Select a new memory configuration/
option.
Max
Performance
Max
Compatibility
Mirror
RAID
View
Configuration
Details
Press Enter to access the View and
Configuration Details submenu.
Set Memory
Hot-plug in
SRAT table
Enables hot-replace and hot-add
memory boards while the system is in
operation.
Yes
No
Parameter Description Option