B-10
ANA-5910/5930/5940 User’s Guide
ANA-5910/5930/5940 User’s Guide
Stock Number: 510694-00, Rev. C Page: B-10
Print Spec Number: 493081-00
Current Date: 5/28/97 ECN Date: 05/29/97
W5154 incompatible configuration
program
The wrong version of
acipcnfg.exe
or
aarpcnfg.exe
is being used.
W5155 lis already started An attempt was made to start the LIS
while it was already started. If you
want to change the configuration of
the LIS, stop the driver, configure it,
and then restart it.
W5156 is already shutdown An attempt was made to shut down
the LIS while it was already shut
down. No action is required.
W5160 out of memory Occurs if all system memory has been
used up; generally occurs if a fast
machine is streaming data to a slow
machine, or some other mismatch in
application or machine speed occurs
causing the slower one to be
overloaded. Change the system
resource parameters or allow fewer
users to use your system at one time.
W5301 arp lookup failed - check pvc
configuration
In a PVC only environment, look up
the ATMARP table for the destination
IP address failed. As there is no
ATMARP server in a PVC only
environment, the destination is
unreachable. Check that the VPI/VCI
numbers are the same on the end
points and on the switch.
W5310 no source ip address in arp
message
W5311 remote station claiming same
ip address
W5312 message from wrong subnet
received
An invalid ATMARP or inverse
ATMARP message was received.
Check for conflicts between the IP
addresses assigned to each interface.
All IP stations must have the same
address prefix, that is, be in the same
subnet, for a Classical IP LAN. IP
stations in different subnetworks must
communicate via a router.
Driver Console Error Message Description