Diagnostics Menu 59
p Use LEFT or RIGHT to select the desired field. Select the drive row and drive using UP or DOWN. Press
ENTER to activate.
rr = Row number (01 - 2)
dd = Drive number (01 - 04)
This function is usually used for diagnostics only by a trained technician.
Map Slots
The Map Slots function will cause the Scalar Library to update its cartridge inventory log. Selecting “N” in the
Scan Barcodes field will prevent the library from updating its barcodes inventory log. If the Barcode Scanner
configuration parameter is set to “N”, the setting of the Scan Barcodes field is ignored.
p Use LEFT or RIGHT to select the Scan Barcodes field. Use UP or DOWN to select Y or N. Press
ENTER to activate.
This function is usually used for diagnostics only by a trained technician.
Calibrate X and Y
The Calibrate X and Y function will cause the Scalar Library to move the Media Picker to the home position (x
= left, y = bottom) and update its home position constant.
p Press ENTER to activate.
This function is usually used for diagnostics only by a trained technician.
Test Secondary Fan
The Test Secondary Fan function will cause the Scalar Library to turn the secondary cooling fan on or off.
Exiting this function via either the ESC or MENU key will turn off the secondary fan, unless the thermal IC on the
Main Controller board reads 45º C or more.