ADIC Server Server User Manual


 
4-58 DAS ACI Functions
601626-B
If the eject area is full the system stops the eject procedure.
Depending on the DAS_EJECTAREAFULL environment
variable on the AMU, the command will be canceled, or the
system starts with the next eject after the operator has
removed cartridges from the eject area.
The attribute of the coordinate will be set to empty in the
AMU database. The volser will be set to 0000000000000000,
and the type will be set to AMU-Dynamic. The compartment
is ready for the other volsers.
The compartments for cleaning cartridges are not reserved.
Organize enough compartments for the cleaning cartridges
every time.
For additional information, refer to aci_insert on page 4-75,
and aci_eject2 on page 4-42.
Return Values
0: The call was successful.
-1: The call failed.
The external variable d_errno is set to one of the following
DAS error codes:
ERPC
EINVALID
ENOVOLUME
EPROBVOL
EAMU
EAMUCOMM
EROBOTCOMM
EDASINT
ENOAREA
ENOTAUTH
aci_ei_info returned information to each ejected volser
volser volser of the ejected volume
type media type of the named volser
Refer to Media Types on page 2-7
errcode error code derrno
Table 4-21 Parameters for the aci_ejectclean Function Call
Parameter Description