4-94 DAS ACI Functions
601626-B
The aci_partial_inventory function is intended for testing
and startup. An error function will be displayed in the AMU
log during operation (and not returned to the calling
process). The database segments that are defined in the
function cell will be overwritten with a symbolic volser
“*Ixxxx” if the barcode reader malfunctions.
Table 4-36 Parameters for the aci_partial_inventory Function Call
Parameter Description
SourCoor 10 digit logical coordinate of the device for the start of the
inventory (defined in the AMU database), e.g. L501010101
TargetCoor 10 digit logical coordinate of the device for the end of the
inventory (defined in the AMU database), e.g. L501011310
Source and targeted must be in the same device.
Attentio