Overview A-3
21 Dec 2001
A-
Overview
This section contains information on error recovery
procedures and explanations of terms used throughout this
document.
Error Recovery Procedures
This section contains information on error recovery
procedures. See Table A-1.
Table A-1 Error Code Reactions
Number d_error Name Recommended Reactions to the Error Code
0EOK No error.
1 ERPC Communication problem, test the TCP/IP to the
AMU PC and, if possible, try an alternate route.
2 EINVALID A parameter in the command is wrong, try it with
other parameters.
3 ENOVOLUME Volser from the command with the media type is
not found in the AMU database. Check the media
type in the command. If a mismatch is detected
between the archive and the database, update the
AMU database with the inventory command.
Otherwise try the command with another volser
4 ENODRIVE The drive parameter in the command does not
match any drives in the AML. Change the
parameter in the command.
5 EDRVOCUPPIED The drive named is already used for another
cartridge.
• Send an unload command to the drive.
• Send a dismount command to the DAS
software.
• Wait until the previous mount (also possible for
cleaning) is completed.