4-118 DAS ACI Functions
601626-B
aci_shutdown
The aci_shutdown function shuts down the DAS software. See
Figure 4-108.
Figure 4-108 aci_shutdown Function Call
This function shuts down the DAS server. Once the request
has been accepted, no other request will be accepted. A restart
of the DAS server is necessary to resume DAS operations. See
Table 4-48.
Return Values
• 0: The call was successful.
• -1: The call failed.
The external variable d_errno is set to one of the following
DAS error codes:
• ERPC
• EDASINT
• ESWITCHINPROG
Refer to Figure 4-109 on page 4-119 for an example of the
aci_shutdown function.
Table 4-48 Parameter for the aci_shutdown Function Call
Parameter Description
now By default, DAS waits for outstanding requests to be
completed before termination. It however, the now parameter
or the now string is specified, the shut down is immediate.
#include "aci.h"
int aci_shutdown (char *now)