A SERVICE OF

logo

Section 4, User Interface Guide ATLAS 550 System Manual
102 © 2002 ADTRAN, Inc. 61200305L1-1F
MODULES
Write security: 3; Read security: 5
The MODULES menu provides status information and menu options that allow you to configure and control
the installed option modules as well as the network ports (see Figure 8).
Figure 8. Modules Menu
MODULES > SLT
Read security: 5
Identifies the slot number. Slot 0 refers to the ATLAS 550 Base Unit.
The ATLAS 550 has three types of slots: network slots, option module slots, and resource module slots.
The two network slots are designated
NTW1 and NTW2. The four option module slots are designated SLT1
through
4, and the four resource module slots are designated RSC1 through 4. Resource modules are
installed onto any option module, but not onto network modules.
If you install a module in a slot, then want to install a different type of module in the slot,
you must set this field to
EMPTY before selecting another module type.
If a module is installed, the module type automatically shows the name of the installed
module, and it cannot be set to any other option.