Advantech EKI-7758F Switch User Manual


 
EKI-7758F User Manual 6
Power Consumption
Max. 17 W
Power Input
2 x Unregulated +12 ~ 48 V
DC
Fault Output
1 Relay Output
Mechanism
Dimensions (WxHxD)
79 x 152 x 105 mm
Enclosure
IP30, metal shell with solid mounting
kits
Mounting
DIN-rail, wall
Protection
ESD (Ethernet)
4,000 V
DC
Surge (EFT for power)
3,000 V
DC
Power Reverse
Present
Overload
3.2A / 60V Replaceable Fuse
Environment
Operating Temperature
-10 ~ 60 (14 ~ 140 )
Operating Humidity
5 ~ 95% (non-condensing)
Storage Temperature
-40 ~ 85(-40~185 )
Storage Humidity
0 ~ 95% (non-condensing)
MTBF
289,774 hours
Certifications
Safety
UL, 60950-1, CAN/CSA-C22.2 No.60950
EMC
U.S.A.: FCC Part 15 CISPR 22
EU: EN55011, EN61000-6-4
EN55022, Class A,
EN61000-3-2/3
EN55024
IEC61000-4-2/3/4/5/6/8/11/12
EN61000-6-2
Freefall
IEC60068-2-32
Shock
IEC60068-2-27
Vibration
IEC60068-2-6