Allied Telesis X610-48TS Switch User Manual


 
How to Configure and Use AMF on Allied Telesis Switches | Page 23
Configuring AMF
Member3(config)#int port1.0.1
Member3(config-if)#switchport atmf-link
Member3(config-if)#switchport trunk allowed vlan add 2-3
Member3#copy running-config startup-config
Building configuration...
[OK]
Member3#reload
reboot system? (y/n): y
Configuration Member 4
awplus#conf t
awplus(config)#hostname Member4
Host names must be unique within the AMF network.
Member4(config)#atmf network-name atmf1
Note:
The AMF network name must be the same on all nodes within the AMF network, and
the device must be rebooted before the AMF network name takes effect.
Member4(config)#vlan database
Member4(config-vlan)#vlan 2-3
Member4(config)#no spanning-tree rstp enable
Member4(config)#int port1.0.1
Member4(config-if)#switchport atmf-link
Member4(config-if)#switchport trunk allowed vlan add 2-3
5. Configure ports as AMF-links.
6. Configure data VLANs on the AMF links as required.
7. Save the configuration and reboot the switch.
1. Set the host name.
2. Set the AMF network name.
3. Configure data VLANs
4. Disable RSTP globally (this is enabled by default).
5. Configure ports as AMF-links.
6. Configure data VLANs on the AMF links as required.