Battery Life and Replacement
158
MVP-5200i Modero Viewpoint Widescreen Touch Panel
Battery Replacement
The touch panel's battery is intended to last the life of the device, but in cases where the battery has
reached its effective end of life, it may be replaced with the MVP-BP-52 Battery Pack Kit (FG5966-20).
To replace the battery:
1. Shut down the device.
2. Place the device face-down and remove the five screws from the back of the device (FIG. 90).
Two of the screws are at each of the upper corners of the device, underneath screw covers.
Remove the screw covers to access the screws.
Lift up the kickstand to reach the remaining three screws.
3. Carefully remove the back of the device, making sure not to dislodge the IR emitter panel.
4. Disconnect and remove the old battery from the female connector (FIG. 91).
5. Connect the new battery, making sure to seat fully the battery’s female connector to the male
connector in the device. Use a clean, nonconductive stick or probe to seat the connectors.
6. Install the new battery, making sure that the label faces outward and the battery connector wiring
runs to the left (FIG. 91). Make sure that the excess battery wiring fits in the space to the bottom left
of the battery.
7. Reattach the back of the device.
FIG. 90 Screw placement at the back of the MVP-5200i- GW
FIG. 91 Battery installation and connection diagram
Upper screw covers
Lower screws
Kickstand
IR emitter panel
Battery
Female connector
Excess battery wiring