ATEN Technology SN0108 Computer Drive User Manual


 
53
Chapter 6
Out of Band Operation
Overview
In case the network goes down, or the SN0108 / SN0116 cannot be accessed
with the usual browser based method for some other reason, the SN0108 /
SN0116 can be reached via several additional Out of Band (OOB) methods.
These include HyperTerminal, PPP, Telnet, and SSH. Each of these is
described in the sections that follow.
HyperTerminal
HyperTerminal is a program included with Windows. It can be used to
establish either a direct terminal connection, or an indirect (phone in) terminal
connection. Both configurations are discussed below.
Direct HyperTerminal Connection
Setup:
To set up a direct HyperTerminal connection, do the following:
1. Use Ethernet cable and a DTE-to-DTE adapter to connect one of the
SN0108 / SN0116's serial ports to a COM port on a PC (see the
Installation section, pages 13 and 14).
Note: 1. See RJ-45 to Serial Adapters, page 96, for details on choosing the
appropriate adapter. The usual choice for connecting to a PC is
SA0141.
2. In the examples that follow we use COM1. If you use a different
COM port, change the settings accordingly.
3. Be sure that the port you specify as the Console Port in the OOBC
dialog box (seeOOBC, page 28) matches the port that you are
connecting the PC to. Change the setting, if necessary.