Avaya G3PBX Network Router User Manual


 
Troubleshooting
Issue 1 — December 2002
4-13DEFNETM.PDF — Avaya CT 1.2
On the other hand, if there are multiple G3PDs on multiple Tservers
and this occurs, then two clients are using the same link. This is an
error condition. Change the configuration so that both clients are
not using the same link.
Invalid Client — The G3PD is not known to the DEFINITY LAN
Gateway application. Check the brouter administration on the
DEFINITY LAN Gateway. Verify that the brouter administration and
G3PD configuration are consistent.
Offline — A user has run an OA&M Offline command to take the link
off line. Use the DEFINITY G3PD Administrator utility’s Online
command to bring the link back on line. See ‘‘Offline/Online
Command’’ in Chapter 3.
If you need help with DEFINITY switch or DEFINITY LAN Gateway problems,
contact the Customer Care Center at:
1-800-344-9670
How Dropped Link Affects T
elephony Services Requests
If a particular link goes down, all existing requests associated with that link
(monitors, etc.) will be aborted by the switch. The client receives:
a CSTA Universal Failure Confirmation event for each outstanding request
(cstaMakeCall(), etc.). An outstanding CSTA request is one that has not
yet received a confirmation event. The error code in the CSTA Universal
Failure event is set to RESOURCE_OUT_OF_SERVICE (34).
The user should reissue the request. If other links are available, the new
request will succeed. If no other links are available, the client will continue
to receive RESOURCE_OUT_OF_SERVICE (34) and should assume
service is unavailable.
a Monitor Ended event for any previously established monitors. The cause
is EC_NETWORK_NOT_OBTAINABLE (21). The client should
re-establish the monitor request. This may require restarting the
application. If other links are available, the monitor request is honored. If
no other links are available, the client receives a CSTA Universal Failure
Confirmation with the error code returned RESOURCE_OUT_OF_
SERVICE (34) and should assume service to the switch is unavailable.
a Route Register Abort event is sent to the application when all of the CTI
links that support the routeRequestEvents for the registered routing device
are down. The application could make use of System and Link Status
Notification to determine when the link comes back up. If the application
wants to continue the routing service after the CTI link is up, it must issue a
cstaRouteRegisterReq() to re-establish a routing registration session for
the routing device.