Avocent ACS 6000 Network Card User Manual


 
Chapter 4: Using the Web Manager 51
Event Notifications - Settings
The following table describes the screens and the actions you need to take to configure Event
Notifications.
Table 4.3: Event Notifications - Settings Screen Description
Name Description
Syslog: Facility There are six choices available from the pull-down menu: LogLocal 0, LogLocal
1, LogLocal 2, LogLocal 3, LogLocal 4 or LogLocal 5.
SNMP Trap: Community Enter the name of the community defined in one or more of the SNMP trap
servers.
NOTE: The community name must be the same for all SNMP trap servers.
SNMP Trap: Server 1 - 5 Enter the IP address of up to five SNMP trap servers in the fields provided.
SMS: Server Enter the IP address of the SMS server.
SMS: Port Enter the port number for use with the SMS server.
SMS: Pager Number Enter the pager number to which the SMS event will be sent.
Email: Server Enter the IP address of the email server where event notifications will be sent.
Email: Port Enter the port number of the email server to be used for event notifications.
Email: Destination Email Enter the email address of the event notifications recipient.
DSView: DSView 3 Server Enter the IP address of the DSView 3 server where event notifications will be
sent.
DSView: Syslog Server
Port
Enter the syslog server port number for the DSView 3 server.
DSView: SSH Server Port Enter the SSH server port number for the DSView 3 server.
DSView: SSH User Name Enter the SSH username for the DSView 3 server.
DSView: SSH Idle Timeout
(sec)
Enter the SSH idle timeout (in seconds) for the DSView 3 server, used to close
the SSH tunnel if it is idle.
DSView: SSH Start
Threshold (bytes)
Enter the SSH start threshold in bytes for the DSView 3 server, used to set up
the parameters if the DSView 3 server does not respond.
DSView: SSH Tunnel
Buffer Size (bytes)
Enter the SSH tunnel buffer size in bytes for the DSView 3 server, used to set up
the parameters if the DSView 3 server does not respond.
DSView: Buffer Full First
Warning (bytes)
Enter the number of bytes allowed by the DSView 3 buffer before the first buffer
full event notification is sent (when DSView 3 server does not respond).
DSView: Buffer Full Second
Warning (bytes)
Enter the number of bytes allowed by the DSView 3 buffer before the second
buffer full event notification is sent (when DSView 3 server does not respond).