Barco R9001330 Barcode Reader User Manual


 
Connections
Connections
5975288 BARCOGRAPHICS 8200 110497
7-11
7-11
5975288 BARCOGRAPHICS 8200 110497
RGB3S/RG3sB input module.
Connect your RGB signals with Tri-level sync, e.g. a professional
VCR to the RGB 3 level sync input module.
RGB3S/RG3sB analog : 5 x BNC
Red :0.7 Vpp ± 3 dB
Blue : 0.7 Vpp ± 3 dB
Green : 0.7 Vpp ± 3 dB
1 Vpp ± 3 dB if Tri-level sync on green
Vert. Tri-level sync : 1 Vpp to 4 Vpp ± 3 dB
Hor. Tri-level sync / Composite Tri-level sync:
1 Vpp to 4 Vpp ± 3 dB
All input signals are always 75 ohm terminated, even in the "not
selected" mode.
Input selection :
R
G
B
H / C
V
On
RGB 3-LEVEL SYNC INPUT
98 27920
Vert. 3 level
sync
Blue
Green
Red
Hor. or composite
3 level sync
HDTV VCR
R
G
R
G
RS 232 IN
100 - 230 V
9 - 4 A
60 - 50 Hz
RS232 OUT
0
I
This device complies with Par t 15 of the FCC rules . Operation
is subject to f ollowing two conditions :
(1) This device may not cause harm ful interference
(2) This device must accept any interference rec eived
including interf erence that m ay cause undesired oper ation
IR-ACKNOWLEDGED
IR-RECEIVED
DIAGNOSTICS
CODE
IR-RECEIVER
Key in the corresponding slot number on the RCU or the local
keypad.
Indication on the input slot menu :
RGB3L-SS = RGB with separate Tri level sync.
RGB3L-SOG = RGB with Tri level sync on green.
RGB3S/RG3sB input module.
Connect your RGB signals with Tri-level sync, e.g. a professional
VCR to the RGB 3 level sync input module.
RGB3S/RG3sB analog : 5 x BNC
Red :0.7 Vpp ± 3 dB
Blue : 0.7 Vpp ± 3 dB
Green : 0.7 Vpp ± 3 dB
1 Vpp ± 3 dB if Tri-level sync on green
Vert. Tri-level sync : 1 Vpp to 4 Vpp ± 3 dB
Hor. Tri-level sync / Composite Tri-level sync:
1 Vpp to 4 Vpp ± 3 dB
All input signals are always 75 ohm terminated, even in the "not
selected" mode.
Input selection :
R
G
B
H / C
V
On
RGB 3-LEVEL SYNC INPUT
98 27920
Vert. 3 level
sync
Blue
Green
Red
Hor. or composite
3 level sync
HDTV VCR
R
G
R
G
RS 232 IN
100 - 230 V
9 - 4 A
60 - 50 Hz
RS232 OUT
0
I
This device complies with Par t 15 of the FCC rules . Operation
is subject to f ollowing two conditions :
(1) This device may not cause harm ful interference
(2) This device must accept any interference rec eived
including interf erence that m ay cause undesired oper ation
IR-ACKNOWLEDGED
IR-RECEIVED
DIAGNOSTICS
CODE
IR-RECEIVER
Key in the corresponding slot number on the RCU or the local
keypad.
Indication on the input slot menu :
RGB3L-SS = RGB with separate Tri level sync.
RGB3L-SOG = RGB with Tri level sync on green.