Black Box LRU4240 Network Router User Manual


 
Dual Trunk E1 Router
Dual Trunk E1 Router User’s Guide TECHNICAL: 0118 96 56 000 149
unit(config)#
t1 lbo
Use the t1 lbo command to to set the Line Build Out (LBO) value to be used for tuning the circuit attenuation between the unit
and the last repeater on the T1 circuit.
Command Syntax: t1 lbo [0dB | -7.5dB | -15 dB]
Command Mode: Config
Example
t1 timeslot
Use the t1 timeslot command to allocate an T1 timeslot and assign it to data, voice or idle.
Command Syntax: t1 timeslot <1-23> [aux | f1 | idle]
<1-31> select an E1 timeslot number
aux Assign selected timeslot to auxiliary dro-and-insert port
f1 Assign selected timeslot to Ethernet data port
idle Selected timeslot will not be used
Command Mode: Config
Example
Assign timeslot 10 to transport data from Ethernet data port.
unit(config)#e1 timeslot 10 f1
time-sync
Use the time-sync command to configure the RFC-868 time protocol client.
Command Syntax:
time-sync [enabled | disabled] Enable of disables time synchronization.
time-sync attempt-count [1-30]
time-sync attempt-interval [1-10]
time-sync frequency days [0-99]
time-sync frequency hours [0-23]
time-sync frequency minutes [0-59]
time-sync frequency seconds [0-59]
time sync primary-ip A.B.C.D
time-sync secondary-ip A.B.C.D
time-sync port [enet | net | comm]
time-zone
Use the time-zone command to configure the GMT time zone.
Command Syntax:
time-zone ahead-gmt [yes | no]
time-zone day-light-savings [enabled | disabled]
time-zone day-light-savings diff-minutes [0-59]
time-zone day-light-savings start-month [0-12]
time-zone day-light-savings start-week [0-5]
time-zone offset-gmt minutes [0-59]
time-zone day-light-savings diff-hours [0-12]
time-zone offset-gmt hours [0-12]
traffic monitoring
Use the traffic monitoring command to enable or disable RMON1 and RMON2 traffic monitoring.
Command Syntax:
traffic monitoring [enabled | disabled]