111
TROUBLESHOOTING AND MAINTENANCE
3
Wipe the electric terminals with isopropyl alcohol on a cotton swab.
4
Wipe the gears with a clean dry cloth.
5
Gently wipe the scanner window and the toner sensor with a clean soft
dry cloth. Do NOT use isoproply alcohol to clean the scanner window
or the toner sensor.
Cleaning the Drum Unit
We recommend you place the drum unit on a drop cloth or large piece of
disposable paper to avoid spilling and scattering toner.
1
Carefully turn the drum unit upside down.
2
Clean the primary corona wire inside the drum unit by gently sliding
the tab from right to left several times.
3
Return the tab to the home position (
▼
mark position) before
reinstalling the drum unit.
Tab
Corona
Wire
Home
Position
(
▼
)
CAUTION
If you do not position the tab at the home position, printed pages may have
vertical stripes.
4
Install the drum unit into the fax machine.
See “Replacing the Drum Unit” on pages 117–121.
5
Close the top cover.
6
Plug in the power cord.