Brother MFC-8480DN/8880DN/8890DW Fax Machine User Manual


 
3-36
Confidential
Error code D1
Modem initialization failed
Error code DD
Fuser error other than 58, 59, 68, 69, 6A, 6B, 6C, 6D, 6E, 6F, 76, 78, DE and E2 are
occurred.
Error code DE
Central temperature of heat roller detected the temperature that was lower than edge (60°C)
Error code E0
Program error
Machine Error D1
Step Cause Remedy
1 Main PCB failure Replace the main PCB ASSY.
Fusser Error
Turn the power off, then on again. Leave the machine for 15min.
Step Cause Remedy
1 Fuser unit failure Replace the fuser unit.
2 Main PCB failure Replace the main PCB ASSY.
3 LVPS PCB failure Replace the LVPS PCB ASSY.
Fusser Error
Turn the power off, then on again. Leave the machine for 15min.
Step Cause Remedy
1
Relay rear PCB ASSY connection
failure
Reconnect the relay rear PCB ASSY
connector correctly.
2 Main PCB failure Replace the main PCB ASSY.
Print Unable E0
Turn the power off and then back on again.
Step Cause Remedy
1 Program failure Reinstall the latest firmware.
2 Main PCB failure Replace the main PCB ASSY.