3-63
Confidential
(2) Command reception
(3) Communication code compatibility [checking the NSF and DIS]
Code 1 Code 2 Causes
20 01 Unable to detect a flag field.
20 02 Carrier was OFF for 200 ms or longer.
20 03 Abort detected (“1” in succession for 7 bits or more).
20 04 Overrun detected.
20 05 A frame for 3 seconds or more received.
20 06 CRC error in answerback.
20 07 Echo command received.
20 08 Invalid command received.
20 09
Command ignored once for document setting or for
dumping-out at turn-around transmission.
20 0A T5 time-out error
20 0B CRP received.
20 0C EOR and NULL received.
Code 1 Code 2 Causes
32 01
Remote terminal only with V.29 capability in 2400 or
4800 bps transmission.
32 02 Remote terminal not ready for polling.
32 10
Remote terminal not equipped with password function
or its password switch OFF.
32 11
Remote terminal not equipped with or not ready for
confidential mailbox function.
32 12
Remote terminal not equipped with or not ready for relay
broadcasting function.
32 13 No confidential mail in the remote terminal.
32 14
The available memory space of the remote terminal is
less than that required for reception of the confidential
or relay broad-casting instruction.
32 18 Remote terminal not equipped with color function.