Error code 1E
Replacement time of the drum unit.
Error code 1F
Two or more optional trays are installed.
Error code 24
Internal temperature sensor failure
Drum End Soon
User Check
Replace the drum unit with a new one.
Too Many Trays
User Check
Install one optional tray.
Step Cause Remedy
1 Connector: 54702-1219 failure Replace the connector: 54702-1219.
2 Main PCB failure Replace the main PCB ASSY.
Print Unable 24
Turn the power off and then back on again.
Step Cause Remedy
1
Harness connection failure of
internal temperature sensor
Check the harness connection of the
internal temperature sensor and reconnect
it.
2 Internal temperature sensor failure Replace the internal temperature sensor.
3 Main PCB failure Replace the main PCB ASSY.