Cabletron Systems 2M46 Switch User Manual


 
Chapter 3: LM Security Screens for 2H23-50R/2H33-37R Devices
3-14 Local Management Supplement
2. Use the SPACE bar to step to the appropriate connector (CONN)
number.
3. Press ENTER to display the 12 repeater ports of the selected
connector.
4. Use the arrow keys to highlight the Security State field for the desired
repeater port.
5. Use the SPACE bar to step to the appropriate security level
(NonSecure, LockOnNext, or LockedOnAddr).
6. If the security level chosen causes the DisablePort and SendTrap
fields to display under Action On Intruder, use the arrow keys to
highlight the DisablePort field.
If the security level chosen does not cause the fields to display under
Action On Intruder, proceed to step 10.
7. To change the DisablePort setting to NoDisable, press the SPACE
bar to toggle the setting.
8. Use the arrow keys to highlight the SendTrap field.
9. To change the setting to NoTrap, press the SPACE bar to toggle the
setting.
10. If the security state selected is LockedOnAddr, use the arrow keys to
highlight the Address field for the repeater port. Otherwise go to
step 12.
11. Enter the MAC address to lock on, using the numerical keys. When
entering the address, it is not necessary to include dashes in the
number.
12. To change the security on more than one repeater port, repeat steps 4
through 11 for each port.
13. After configuring the repeater ports, use the arrow keys to highlight
the SAVE command.
14. Press ENTER. The message “SAVED OK” displays and all
configured settings for all repeater ports of the connector are saved.
15. If the ports on another connector need to be configured, repeat steps 1
through 14.