Cabletron Systems 6H122-08 Switch User Manual


 
Chapter 3: Installation
3-10 6H122-08 User’s Guide
2. Insert one end of the SC connector into the FE-100FX or FE-100F3
installed in the 6H122-08. See Figure 3-5.
3. At the other end of the fiber optic cable, attach the SC connector to the
other device.
Figure 3-5 FE-100FX and FE-100F3 Port
4. Verify that a link exists by checking that the port RX LED is on
(flashing amber, blinking green, or solid green). If the RX LED is off
and the TX LED is not blinking amber, perform the following steps
until it is on:
a. Check that the power is turned on for the device at the other end of
the link.
b. Verify proper crossing over of fiber strands between the
applicable port on the 6H122-08 and the fiber optic device at the
other end of the fiber optic link segment.
c. Verify that the fiber connection meets the dB loss specifications
outlined in the Cabletron Systems Cabling Guide.
If a link has not been established, contact the Cabletron Systems Global
Call Center. Refer to Section 1.7, for details.
NOTE
The port RX LED flashes green and amber during bootup.
RX LED
2159-06
87