Cabletron Systems 6H122-08 Switch User Manual


 
Port Redirect Function Screen
6H122-08 User’s Guide 5-31
Figure 5-14 Port Redirect Function Screen
The following definitions briefly explain each field of the Port Redirect
Function screen.
Source Module (Read-Only)
Displays which modules are currently set as source modules.
Source Port (Read-Only)
Displays which ports are currently set as source ports.
Destination Module (Read-Only)
Displays which modules are currently set as destination modules.
Destination Port (Read-Only)
Displays which ports are currently set as destination ports.
Remap Errors (Read-only)
Displays whether the corresponding source modules and ports are
configured to send errored frames to the destination modules and ports, or
to drop all errored frames before forwarding traffic.
Source Module [
n
] (Selectable)
Allows a selected module [n] to be configured as a source module.
Port Redirect Function
2159_38
Port
1
1
1
2
2
3
3
3
Module
3
3
3
1
3
4
5
5
Module
1
1
1
2
2
3
3
3
Port
2
3
4
1
3
4
5
8
Source Destination Remap Errors
ON
ON
ON
OFF
ON
ON
ON
OFF
============ ============ ============
6C105 LOCAL MANAGEMENT
Event Message Line
SAVE
PREVIOUS
RETURN
NEXT
Source Port [1]
Destination Module [1]
Status [ADD]
Source Module [1]
Destination Port [1]
RETURN
EXIT
Errors [ON]