Cabletron Systems SmartCell 6A000 Switch User Manual


 
SmartCell 6A000 User Guide 4-5
Switch Administration Settin
g
Up Routes
From SW2, enter
SmartCell ZX # show iisproute
Entry# Port# Metric Len Address
============================================================================
0 A4 1 104 39:00:00:00:00:00:00:00:00:00:14:41:80
SmartCell ZX #
5. If clients on both switch SW1 and SW2 are within the same subnet, you can test connectivity by
pinging between clients.
IISP Routes Amon
g
Multiple Switches
Multiple IISP routes can be set up over a single physical link. Continuing with the example above, a third switch (SW3)
is added.
6. Connect a cable between port B1 of SW2 and port B1 of SW3; then add an IISP route between B1
of SW2 and B1 of SW3 (see Figure 4-1).
7. Use the add iisproute command to add a third route from SW1 to SW3 over the existing cables.
On switch SW1, enter:
SmartCell ZX # add iisproute
ATMAdress() : 39:00:00:00:00:00:00:00:00:00:14:15:00
<SW3's netprefix
PortNumber(A1) :a4
<Port on SW1 attached to the cable from A4 on SW2
Metric(1) :
SmartCell ZX #
On switch SW3, enter
SmartCell ZX # add iisproute
ATMAdress() : 39:00:00:00:00:00:00:00:00:00:14:41:80
<SW1's netprefix
PortNumber(A1) :b1
< Port on SW3 attached to the cable from B1 of SW2
Metric(1) :
SmartCell ZX #
SW1 and SW3 are connected without using a dedicated physical connection between the two switches.
Note that a routing loop is created if SW1 and SW3 are physically connected with a cable and an IISP route is defined
over this physical link.