Cisco Systems IAD2430 Computer Hardware User Manual


 
3-19
Cisco IAD2430 Series Integrated Access Devices Hardware Installation Guide
OL-4234-06
Chapter 3 Installing Cisco IAD2430 Series IADs
Connecting Cables
to, or not shielded from, the off-premise wiring or power cables during a lightning strike or power
surge, the on-premise wiring can carry a dangerous discharge to the attached interface, equipment,
and nearby personnel.
Statement 338
Table 3-2 shows the results of the NEBS Type 1/3 power line cross tests performed on the
Cisco IAD2430 series FXS ports.
Note The installation must comply with all applicable codes.
LAN and Power Cables
The LAN and power cables and connections are described in Table 3-3 and shown in Figure 3-17 and
Figure 3-18.
Ta b l e 3-2 Results of the NEBS Power Line Cross Tests on FXS Ports
NEBS Tests Results
50 V/0.33 A; 15 minutes Passed
100 V/0.17 A; 15 minutes Passed
200 V/1.00 A; 1–second pulses, 60 repetitions Passed
Ta b l e 3-3 LAN, Administrative Access, and Power Cable Selection
Port or Connection Color or Type Connected To Cable
Fast Ethernet Yellow Fast Ethernet switch Straight-through Fast Ethernet cable (not included)
Console Light blue PC or ASCII terminal
communication (COM) port
RJ-45-to-DB-9 console cable (included)
Auxiliary Black Modem for remote access RJ-45-to-DB-25 auxiliary cable (included)
Power (not shown) Power 100–240 VAC, 50–60 Hz Grounding power cord (included)
1
1. Power cables vary to meet local requirements.