Appendix C RAID Controller Considerations
Supported RAID Controllers and Required Cables
Supported RAID Controllers and Required Cables
This server supports the RAID controller options and cable requirements shown in Table C-1 for the
small form factor version, or Table C-2 for the large form factor version of the server.
Caution Do not mix controller types in the server. Do not use the embedded MegaRAID controller and a hardware
RAID controller card at the same time. This is not supported and could result in data loss.
Note Dual controllers are not supported.
Note The cables in this section apply to both single- and dual-CPU configurations.
Table C-1 lists the RAID options for the small form factor (SFF) version of the server.
Table C-1 Cisco UCS C22 Small Form Factor RAID Options
Controller Style
Maximum
Drives SCPM
1
1. SCPM = SuperCap power module (the RAID backup unit).
RAID Levels
Supported Required Cables
Embedded
MegaRAID
2
2. The embedded RAID controller must be enabled in the BIOS.
Onboard 4 SATA
(default) or
8 SAS
3
internal
3. Support for eight SAS drives requires an optional SCU upgrade ROM module on the motherboard.
No 0, 1, 5
4
, 10
4. Embedded RAID 5 support requires an optional software key module.
2 mini-SAS:
UCSC-CABLE-AE
LSI MegaRAID
9220-4i
PCIe 4 internal
5
5. The 9220-4i controller can create a RAID array with maximum 4 drives, even if it detects more than 4 drives.
No 0, 1, 10 4 drives: 1 mini-SAS
UCSC-CABLE-A5
LSI MegaRAID SAS
9220-8i
PCIe 8 internal No 0, 1, 10 4 drives: 1 mini-SAS
8 drives: 2 mini-SAS
UCSC-CABLE-A5
LSI MegaRAID SAS
9240-8i
PCIe 8 internal No 0, 1, 5, 10, 50 4 drives: 1 mini-SAS
8 drives: 2 mini-SAS
UCSC-CABLE-A5
LSI MegaRAID SAS
9265CV-8i
PCIe 8 internal SCPM 0, 1, 5, 6, 10, 50, 60 4 drives: 1 mini-SAS
8 drives: 2 mini-SAS
UCSC-CABLE-A5