Cisco Systems SFS 7008 Server User Manual


 
73
Fan Tray Module Status LEDs
Power Supply Module Status LEDs
Green off No power to the Management Interface module, LED failure,
or yellow LED is ON.
Yellow solid on Failure of the Management Interface module. Operator
attention required.
The “!” label indicates a failure.
Yellow blinking Identify a Management Interface module. Assists in identifying
a particular Field Replaceable Unit on the chassis.
This state is initiated by the user.
This LED can be initiated manually by using the diag LED test.
Refer to the Command Line Reference Guide for more
information.
Example:
For example, to run the identity test on Power Supply 1:
config mode -> diag card 15 ->
test led ->
-> start - start flashing
-> stop - stop flashing
Table 5-9: Interpreting the Fan Tray Status LEDs (see Figure 5-6)
Color State Indication
Green over Yellow off No module power, or LED failure.
Green solid on Fan tray is running with no errors detected.
Green off No power to the fan tray, LED failure, or yellow LED is On.
Yellow solid on Failure of the fan tray. Operator attention required.
The “!” label indicates a failure.
Yellow blinking Identify a fan tray module. Assists in identifying a particular
Field Replaceable Unit on the chassis.
This state is initiated by the user.
This LED can be initiated manually by using the diag LED test.
Refer to the Command Line Reference Guide for more
information.
Example:
For example, to run the identity test on Power Supply 1:
config mode -> diag fan 1 ->
test led ->
-> start - start flashing
-> stop - stop flashing
Table 5-8: Interpreting the Management Interface Module Status LEDs (see Figure 5-6)
Color State Indication