Cisco Systems SFS 7008 Server User Manual


 
86
Figure 5-21: Element Manager Sensors Tab
6. Note the OperStatus field. A status of “up” indicates that the sensor is functioning properly.
7. Note the Temperature field. Each slot has an individual temperature sensor. The Alarm and
Shutdown temperatures vary by slot type.
Monitor the System With the CLI
For a complete list of CLI commands, refer to the CLI Reference Guide.
Use the following CLI commands to monitor the Power Supplies, the fans, and the sensors:
Monitor the Power Supplies
show power-supply
Example
Monitor the Fans
•show fan
An oper-status of “up” means that the blower is operating correctly within the fan unit.
Topspin-270> show power-supply
================================================================================
Power-supply Information
================================================================================
ps type oper-status utilization voltage
--------------------------------------------------------------------------------
1 AC up n/a 48
2 AC down n/a 48
================================================================================
Power-supply Seeprom
================================================================================
product pca pca fru
ps serial-number serial-number number number
--------------------------------------------------------------------------------
1 - - - -
2