Cisco Systems SFS 7008 Server User Manual


 
75
LIM Status LEDs
Location
The LIM Status LED is located at the far left of each LIM card (if you are facing the back of the
chassis). Refer to Figure 5-5 for a complete diagram of the back panel of the chassis.
Figure 5-8: LIM Status Indicator LEDs
Interpreting the LIM Status LEDs
InfiniBand Port LEDs
The InfiniBand LED represents the logical link and the logical link activity.
Table 5-13: Interpreting the Chassis ID Status LEDs (see Figure 5-7)
Color State Indication
Green/Yellow off No module power, or LED failure.
Green solid on Chassis ID module is running with no errors detected.
Green off No power to the Chassis ID module, LED failure, or yellow
LED is On.
Yellow solid on Failure of the Chassis ID module. Operator attention required.
The “!” label indicates a failure.
Yellow blinking Identify a Chassis ID module. Assists in identifying a
particular Field Replaceable Unit on the chassis.
This state is initiated by the user.
This LED can be initiated manually by using the diag LED test.
Refer to the Command Line Reference Guide for more
information.
LIM Status Indicator
Table 5-14: Interpreting the LIM Status LED
Color State Indication
Green and
Yellow
off No module power, or LED failure.
Green solid on Line Interface module is running with no errors
detected.
Green off No power to the Line Interface module, LED
failure, or yellow LED is On.
Yellow solid on Failure of the Line Interface module. Operator
attention required.
The “!” label indicates a failure.