Cisco Systems SFS 7008 Server User Manual


 
74
Master Management Connection Status LED
The Master Management Connection Status LED is a single LED that indicates whether that particular
Management Interface module is connected to the system's active master controller.
Refer to Figure 5-5 to view the location of this LED.
Ethernet Management Port RJ-45 connector LEDs
Refer to Figure 5-5 to view the location of this LED.
Chassis ID LEDs
Figure 5-7: Chassis ID LEDs
The Chassis ID Status LED indicates the status of this module.
Table 5-10: Interpreting the Power Supply Status LEDs (see Figure 5-6)
Color State Indication
Green over Yellow off No fan module installed, or LED failure.
Green solid on Power supply is running with no errors detected.
Green off No power to the Power supply, LED failure, or yellow LED is
On.
Yellow solid on Failure of the Power Supply. Operator attention required.
The “!” label indicates a failure.
Table 5-11: Interpreting the Master Management Connection LEDs (see Figure 5-6)
Color State Indication
Green off Management module is not connected to the active master
controller, or is connected to the system's standby master
controller.
Green solid on Management module is connected to the system's active master
controller.
Table 5-12: Interpreting the Ethernet Management Port LEDs (see Figure 5-6)
Location State Indication
Left port LED off Port is not connected or logical link is down.
Left port LED on Port is connected and logical link is up.
Right port LED off No traffic is moving on the Ethernet Management port link.
Logical link may or may not be Up.
Right port LED on Traffic is moving on the Ethernet Management port link.