Scan Line Width
Product Reference Guide 25
Scan Line Width
Scan a bar code below to set the scan line width. A full scan line width is the default. The
medium scan line width is useful for scanning menus or pick-lists.
Laser On Time
This parameter sets the maximum time that decode processing continues during a scan
attempt. It is programmable in 0.1 second increments from 0.5 to 9.9 seconds. The de-
fault Laser On Time is 3.0 seconds.
To set a Laser On Time, scan the bar code below. Next, scan the two numeric bar codes
from Appendix E, Keypad, that correspond to the desired On Time. Single digit num-
bers must be padded with a leading zero. For example, to set an On Time of 0.5 seconds,
scan the bar code below, then scan the “0” and “5” bar codes. If an error is made, or the
selection needs to be changed, scan Cancel on page 166.
NOTE
This feature applies to scanners in Trigger Single Mode only.
*Full Width
Medium Width
NOTE
This feature applies to scanners in Trigger Single Mode only.
Laser On Time