RS-232
34 QuickScan
®
L
Table 6. Terminal Specific RS-232
Parameter
Standard
(Default)
ICL Fujitsu
Wincor-
Nixdorf
Mode A
Wincor-
Nixdorf
Mode B/
OPOS
Olivetti Omron
Transmit
Code ID
N o Ye s Ye s Ye s Ye s Ye s Ye s
Data Transmis-
sion Format
Data as is Data/Suffix Data/Suffix Data/Suffix Data/Suffix
Prefix/Data/Suf-
fix
Data/Suffix
Suffix
CR/LF
(7013)
CR (1013) CR (1013) CR (1013) CR (1013) ETX (1002) CR (1013)
Baud Rate 9600 9600 9600 9600 9600 9600 9600
Parity None Even None Odd Odd Even None
Hardware Hand-
shaking
None
RTS/CTS
Option 3
None
RTS/CTS
Option 3
RTS/CTS
Option 3
None None
Software Hand-
shaking
None None None None None Ack/Nak None
Serial Response
Time-out
2 Sec. 9.9 Sec. 2 Sec. 9.9 Sec. 9.9 Sec. 9.9 Sec. 9.9 Sec.
Stop Bit
Select
One One One One One One One
ASCII Format 8-Bit 8-Bit 8-Bit 8-Bit 8-Bit 7-Bit 8-Bit
Beep On
<BEL>
Disable Disable Disable Disable Disable Disable Disable
RTS Line
State
Low High Low Low
Low = No data
to send
Low High
Prefix None None None None None STX (1003) None
*In the Nixdorf Mode B, if CTS is Low, scanning is disabled. When CTS is High, the user can scan bar codes.
**If Nixdorf Mode B is scanned without the scanner connected to the proper host, it may appear unable to scan. If this happens, scan a
different RS-232 host type within 5 seconds of cycling power to the scanner.
Table 7. Terminal Specific Code ID Characters
ICL Fujitsu
Wincor-
Nixdorf
Mode A
Wincor-
Nixdorf
Mode B/OPOS
Olivetti Omron
UPC-A A A A A A A
UPC-E E E C C C E
EAN-8/JAN-8 FF FF B B B FF