Dell 860 Computer Hardware User Manual


 
About Your System 17
Error: Incorrect memory
configuration. Ensure
memory in slots DIMM1_A
and DIMM1_B, DIMM2_A and
DIMM2_B match identically
in size, speed and rank.
The installed memory modules are
not matched pairs.
See "Memory Module Installation
Guidelines" on page 68.
Error: Remote Access
Controller initialization
failure.
Faulty or improperly installed RAC. Ensure that the RAC is properly
installed. See "Troubleshooting
Expansion Cards" on page 91.
Error 8602: Auxiliary
device failure. Verify
that mouse and keyboard
are securely attached to
correct connectors.
Loose or improperly connected mouse
or keyboard cable; faulty mouse or
keyboard.
Replace the mouse. If the problem
persists, replace the keyboard.
Gate A20 failure Faulty keyboard controller (faulty
system board).
See "Getting Help" on page 103.
General failure The operating system is unable to
carry out the command.
This message is usually followed by
specific information. Take the
appropriate action to resolve the
problem.
IDE Primary drive 0 not
found
Primary drive 0 set as Auto, no disk. Run the System Setup program to
correct the settings. See
"Using the
System Setup Program
" on page 29.
Invalid memory
configuration detected.
Potential for data
corruption exists!
Unsupported DIMMs are installed in
the system, or the memory
configuration is incorrect.
Replace or reconfigure the DIMMs. See
"System Memory" on page 67 for
memory configuration guidelines, a list
of supported DIMMs, and supported
memory configurations.
Keyboard controller
failure
Faulty keyboard controller (faulty
system board).
See "Getting Help" on page 103.
Keyboard data line failure
Keyboard failure
Keyboard stuck key failure
Loose or improperly connected
keyboard cable; faulty keyboard; faulty
keyboard controller.
Ensure that the keyboard is properly
connected. If the problem persists,
replace the keyboard. If the problem
persists, see "Getting Help" on page 103.
Keyboard fuse has failed. Keyboard fuse has failed. Replace the keyboard.
Faulty system board. If the problem persists, the system board
is faulty. See "Getting Help" on page 103.
Manufacturing mode
detected
System is incorrectly configured.
Table 1-4. System Messages (continued)
Message Causes Corrective Actions