Dell 860 Computer Hardware User Manual


 
About Your System 21
The amount of system
memory has changed.
Faulty memory module.
Information only, if you have changed
the memory configuration.
See "Troubleshooting System Memory"
on page 88. If the problem persists, see
"Getting Help" on page 103.
The amount of tested
memory is below the
minimum system
configuration. System
halted!
Invalid memory configuration. See "Memory Module Installation
Guidelines" on page 68.
Faulty memory module. See "Troubleshooting System Memory"
on page 88. If the problem persists, see
"Getting Help" on page 103.
Time-of-day clock stopped Faulty battery; faulty system board. See "Troubleshooting the System
Battery" on page 86. If the problem
persists, see "Getting Help" on page 103.
Time-of-day not set -
please run SETUP program
Incorrect Time or Date settings; faulty
system battery.
Check the Time and Date settings. See
"Using the System Setup Program" on
page 29. If the problem persists, see
"Troubleshooting the System Battery" on
page 86.
Timer chip counter 2
failed
Faulty system board. See "Getting Help" on page 103.
Unexpected interrupt in
protected mode
Faulty or improperly installed memory
modules or faulty system board.
Ensure that all memory modules are
properly installed. See "Memory Module
Installation Guidelines" on page 68. If
the problem persists, see
"Troubleshooting System Memory" on
page 88. If the problem persists, see
"Getting Help" on page 103.
Utility partition not
available
Utility partition is not available on the
hard disk
Create a utility partition on the boot
hard drive. See the CDs that came with
your system.
Warning! No micro code
update loaded for
processor 0
Micro code update failed. Update the BIOS firmware. See "Getting
Help" on page 103.
Table 1-4. System Messages (continued)
Message Causes Corrective Actions