Dell E06S Series Server User Manual


 
About Your System 37
E201A SuperIO
failure.
Power cycle
AC.
SIO failure. Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 203.
E201B Keyboard
Controller
error. Power
cycle AC.
Keyboard controller failure. Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 203.
E201C SMI
initializati
on failure.
Power cycle
AC.
System management
interrupt (SMI)
initialization failure.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 203.
E201D Shutdown test
failure.
Power cycle
AC.
BIOS shutdown test failure. Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 203.
E201E POST memory
test failure.
Check DIMMs.
BIOS POST memory test
failure.
See "Troubleshooting
System Memory" on
page 181.
If the problem persists,
see "Getting Help" on
page 203.
E2020 CPU
configuratio
n failure.
Check screen
message.
Processor configuration
failure.
Check screen for specific
error messages. See
"Troubleshooting the
Processors" on page 190.
Code Text Causes Corrective Actions