Dell E06S Series Server User Manual


 
About Your System 39
E2112 Memory spared
on Card x
DIMM ##.
Power cycle
AC.
The system BIOS spared the
memory because it has
determined the memory has
too many errors.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Troubleshooting
System Memory" on
page 181.
E2113 Mem mirror
OFF on DIMM
## & ##.
Power cycle
AC.
The system BIOS disabled
memory mirroring because
it has determined one half
of the mirror has had too
many errors. "## & ##"
represents the memory
module pair implicated by
the BIOS.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Troubleshooting
System Memory" on
page 181.
I1910 Intrusion
detected.
Check chassis
cover.
System cover has been
removed.
Information only.
I1911 LCD Log Full.
Check SEL to
review all
Errors.
LCD overflow message. A
maximum of ten error
messages can display
sequentially on the LCD.
The eleventh message
instructs the user to check
the SEL for details on the
events.
Check the SEL for details
on the events.
Remove AC power to the
system for 10 seconds or
clear the SEL.
I1912 SEL full.
Review &
clear log.
The SEL is full of events
and is unable to log any
more.
Check the SEL for more
information and then
clear the SEL.
W1100 CPU VCORE
Regulator
temp
exceeding
range. Check
fans.
The regulator temperature
has reached a point outside
of the allowed range.
See "Troubleshooting
System Cooling
Problems" on page 180. If
the problem persists, see
"Getting Help" on
page 203.
Code Text Causes Corrective Actions
book.book Page 39 Wednesday, January 20, 2010 10:20 AM