64 Using the System Setup Program and UEFI Boot Manager
Embedded Server Management Screen
Serial Port Address
(Serial Device 1=COM1,
Serial Device2=COM2
default)
Sets the serial port addresses for the two serial devices.
NOTE: Only Serial Device 2 can be used for Serial Over
LAN (SOL). To use console redirection by SOL, configure
the same port address for console redirection and the
serial device.
External Serial Connector Specifies whether Serial Device 1, Serial Device 2, or
Remote Access Device has access to the external serial
connector.
NOTE: Only Serial Device 2 can be used for Serial Over
LAN (SOL). To use console redirection by SOL, configure
the same port address for console redirection and the
serial device.
Failsafe Baud Rate
(115200 default)
Displays the failsafe baud rate used for console
redirection. BIOS attempts to determine the baud rate
automatically. This failsafe baud rate is used only if the
attempt fails. This rate should not be adjusted.
Remote Terminal Type
(VT 100/VT220 default)
Sets the remote console terminal type, either
VT100/VT220 or ANSI.
Redirection After Boot
(Enabled default)
Enables or disables BIOS console redirection when the
operating system is loaded.
Option Description
Front Panel LCD Options Options are User Defined String, Model Number, or
None.
If the LCD Home screen is set to an option other than
these three choices, the option will be displayed as
"Advanced" in the BIOS. In this event, the option cannot
be changed in the BIOS unless it is changed back to User
Defined String, Model Number, or None through
another LCD configuration utility (such as the iDRAC
Configuration Utility or the LCD panel menu).
User-Defined LCD String You can enter a name or other identifier for the system, to
be displayed on the LCD module screen.
Option Description