Denso BHT-100Q Scanner User Manual


 
132
Execution program not selected
Problem
No user program has been selected as an execu-
tion program to be run when the power is turned
on.
If this error occurs, the BHT beeps five times
(for 0.1 second per beep) and then turns itself
off.
Solution
Run System Mode and select an execution pro-
gram in the SET SYSTEM menu. (For the selecting
procedure, refer to Chapter 2, Subsection 2.5.3,
[4.1].)
Resume data lost
Problem
No resume data has been retained since the BHT
was not normally turned off and then left with no
battery cartridge loaded or with a discharged bat-
tery cartridge loaded even if the resume function
had been set to ON.
The BHT displays this error message for 3
seconds and automatically runs the execution
program from the point of start-up.
Error in System Mode settings
Problem
Your settings made in System Mode contain an er-
ror.
If this error occurs, the System Mode
settings revert to the factory defaults.
The BHT displays this error message for
three seconds and then displays the "No
execution program selected…" message.
Solution
Make your settings in System Mode again.