Denso BHT-100Q Scanner User Manual


 
154
Bar codes Module size Scanning distance
0.15 mm (5.9 mils) 40 to 90 mm (1.6 to 3.5 inches)*
5
0.25 mm (9.8 mils) 40 to 170 mm(1.6 to 6.7 inches)*
6
0.33 mm (13.0 mils) 40 to 200 mm(1.6 to 7.9 inches)*
7
PCS value: 0.9 min., Reflection intensity: 85% min. for white
*
5
Under these conditions: Codabar 10-digit
Narrow bar, Narrow space: 0.15 mm (5.9 mils)
*
6
Under these conditions: Codarbar 10-digit
Narrow bar, Narrow space: 0.25 mm (9.8 mils)
*
7
Under these conditions: EAN-8 Module size: 0.33 mm (13.0 mils)
PDF417 Module size Scanning distance
0.17 mm (6.7 mils) 40 to 100 mm (1.6 to 3.9 inches)*
3
0.25 mm (9.8 mils) 40 to 170 mm (1.6 to 6.7 inches)*
3
0.33 mm (13.0 mils) 40 to 200 mm (1.6 to 7.9 inches)*
3
PCS value: 0.9 min., Reflection intensity: 85% min. for white
*
3
Under these conditions: 1-column, 11-row, Row height: 3 modules,
Error correction level: 1
MaxiCode Cell pitch Scanning distance
0.88 mm (34.6 mils) 45 to 230 mm (1.8 to 9.1 inches)
PCS value: 0.9 min., Reflection intensity: 85% min. for white
The BHT-100Q may fail to read codes due to specular reflection depending upon the
position of the light source, scanning angle of the reading window, and other condi-
tions.
Data Matrix Cell pitch Scanning distance
0.25 mm (9.8 mils) 30 to 110 mm (1.2 to 4.3 inches)*
4
0.33 mm (13.0 mils) 30 to 140 mm (1.2 to 5.5 inches)*
4
0.55 mm (21.7 mils) 30 to 200 mm (1.2 to 7.9 inches)*
4
PCS value: 0.9 min., Reflection intensity: 85% min. for white
*
4
Under these conditions: 36 x 36 cells
Error correction level: ECC200
Black and white label