Edimax Technology ES-5240G+ Switch User Manual


 
76
4-2-13 Rate Limit
Function name:
Ingress and Egress Bandwidth Setting
Function description:
Ingress and Egress Bandwidth Setting function is used to set up the limit of
Ingress or Egress bandwidth for each port.
Parameter description:
Ingress:
Set up the limit of Ingress bandwidth for the port you choose. Incoming
traffic will be discarded if the rate exceeds the value you set up in Data
Rate field. Pause frames are also generated if flow control is enabled.
The format of the packet limits to unicast, broadcast and multicast. Valid
value of Port 1~24 ranges from 128~3968 kbps.
Default: No Limit
Egress:
Set up the limit of Egress bandwidth for the port you choose. Outgoing
traffic will be discarded if the rate exceeds the value you set up in Data
Rate field. Pause frames are also generated if flow control is enabled.
The format of the packet limits to unicast, broadcast and multicast. Valid
value of Port 1~24 ranges from 128~3968 kbps.
Default: No Limit
Fig. 4-25 Rate Limit Configuration